System update
On Tuesday, August 18th, between 12-1pm, a planned system update of DiVA will take place. During this time, DiVA will not be available.
4647484950515249 of 124
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Belysningsnivåer i urbana miljöer - En studie om krav, uppmätta värden och fotgängarnas upplevelser
2026 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Lighting levels in urban pedestrian environments - A study about requirements, measuring values and the pedestrian´s experience (English)
Abstract [sv]

Denna studie undersöker belysningsnivåer i Stockholm stad där faktiska värden ställs mot belysningskrav enligt den europeiska standarden för utomhusbelysning, SS-EN 13201. Genom att undersöka urbana miljöer analyseras sociala aspekter gällande fotgängares upplevelser, i form av trygghet, orienterbarhet och estetisk utvärdering. Studien utgår ifrån interna indikationer som Trafikkontoret i Stockholm har tagit fram, där det tyder på att vissa platser i Stockholm tycks vara överbelysta. Där av mer belysta än vad den europeiska standarden rekommenderar.Syftet med studien är att analysera hur uppmätta värden förhåller sig till och, eventuellt hur de skiljs från, rekommenderade värden som ställs enligt SS-EN 13201, samt att undersöka hur fotgängare upplever platserna utifrån de sociala aspekterna; orienterbarhet, trygghet och estetik. Studien genomförs med hjälp av både kvalitativa och kvantitativa datainsamlingsmetoder. Belysningsmätningarna sker på sex platser i Stockholm för att sedan jämföras med kraven som ställs på respektive plats. På dessa sex platser, samt tre till sker kvalitativa undersökningar genom att fotgängare får svara på enkätfrågor för att tydligt beskriva sina upplevelser från platsen, sätt till trivsel, trygghet och orienterbarhet, utifrån ljusets utformning.Resultatet visar att flera undersökta gångmiljöer uppvisar avvikelser mellan uppmätta värden och värden rekommenderade enligt standarden. I vissa fall mättes platser som överbelysta utan att direkt kopplas till en ökad upplevd trygghet. Studien visar även att platser med definierade belysningsklasser visar på en mer konsekvent belysningsutformning än platser utan belysningsklasser. Platser utan P- och C-klass präglas oftare av en ojämn ljusfördelning vilket leder till bristande orienterbarhet. Enkätsvaren indikerar på att den upplevda tryggheten och trivsamheten ofta korrigerar med ett jämnt fördelat ljus och fördelaktning att kunna se andra människor på ett tydligt sätt, snarare än en hög ljusnivå.Nyckelord: Belysningsstyrka, trygghet, visuell komfort, orienterbarhet, SS-EN 13201.

Abstract [en]

This study examines lighting levels in the city of Stockholm where actual values are evaluated against lighting requirements according to the European standard for outdoor lighting, SS-EN 13201. By examining urban environmental analyses such as social aspects regarding pedestrian experiences, in the form of safety, orientation, and aesthetic evaluation. The study is based on indications from the Stockholm Traffic Office to show places in Stockholm that appear to be overlit in a way that the lighting level is set as a requirement according to the standard.The purpose of the studies is to analyze how measured values relate to and, possibly how they are distinguished from, recommended values set according to SS-EN 13201, and to examine how pedestrians experience the places based on the social aspects; orientation, safety and aesthetics. The study is carried out using both qualitative and quantitative data collection methods. The lighting measurements are carried out at six locations in Stockholm and then compared with the requirements set at each location. At these six locations, as well as three more, qualitative studies are conducted by having pedestrians' answer questionnaires to clearly describe their experiences of the location, in ways of feeling comfortable, safe and orientable, based on the lighting design.The results show that several of the studied pedestrian environments exhibit discrepancies between measured lighting values and the values recommended bu the standard. In some cases, locations were measured as over-illuminated without this being directly associated with increased perceived safety. The study also indicates that environments with defined lighting classes display a more consistent lighting design than locations without P- and C-class classification are more frequently characterized by uneven light distibutuin, which leads to reduced orientability. The questionnaire responses indicate that perceived safety and comfort correlate more strongly with evenly distributed lighting and the ability to clearly perceive other people, rather than with high lighting levels alone.Keywords: Illuminance, safety, visual comfort, orientable, SS-EN 13201.

Place, publisher, year, edition, pages
2026.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hj:diva-73439OAI: oai:DiVA.org:hj-73439DiVA, id: diva2:2088972
External cooperation
Stockholms stad
Supervisors
Examiners
Available from: 2026-08-04 Created: 2026-07-30 Last updated: 2026-08-04Bibliographically approved

Open Access in DiVA

fulltext(3722 kB)22 downloads
File information
File name FULLTEXT01.pdfFile size 3722 kBChecksum SHA-512
f396ecf10379fe050404e4f080a484bfdc1baa58ff32f42ffb8e1a66f394f91577d99e38f60633bbf36c07ee97537839d1b1cb02c9ee080234332695c1672589
Type fulltextMimetype application/pdf

Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 71 hits
4647484950515249 of 124
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf