Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Enhanced self-assessment of CPR by low-dose, high-frequency training
Jönköping University, Hälsohögskolan, HHJ, Avd. för omvårdnad.ORCID-id: 0000-0002-1641-6321
Karlstad University.
University of Borås.
2021 (Engelska)Ingår i: International Journal of Emergency Services, ISSN 2047-0894, E-ISSN 2047-0908, Vol. 10, nr 1, s. 93-100Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose - The purpose was to investigate what effect an intervention of low-dose, highfrequencycardiopulmonary resuscitation (CPR) training with feedback for one month wouldhave on professionals’ subjective self-assessment skill of CPR.

Design/methodology/approach - This study had a quantitative approach. In total, 38firefighters performed CPR for two minutes on a Resusci Anne QCPR. They then self-assessedtheir CPR through four multiple-choice questions regarding compression rate, depth, recoil, andventilation volume. After one month of low-dose, high-frequency training with visual feedback,the firefighters once more performed CPR and self-assessed their CPR.

Findings - With one month of low-dose, high-frequency training with visual feedback, the levelof self-assessment was; 87% (n=33) correct self-assessment of compression rate, 95% (n=36)correct self-assessment of compression depth, 68% (n=26) correct self-assessment of recoil and87% (n=33) correct self-assessment of ventilations volume. The result shows a reduced numberof firefighters who overestimate their ability to perform CPR.

Originality/value - With low-dose, high-frequency CPR training with visual feedback for amonth, the firefighters develop a good ability to self-assess their CPR to be performed withinthe guidelines. By improving their ability to self-assess their CPR quality, firefighters can selfregulatetheir compression and ventilation quality.

Ort, förlag, år, upplaga, sidor
Emerald Group Publishing Limited, 2021. Vol. 10, nr 1, s. 93-100
Nyckelord [en]
CPR, self-assessment, objective visual feedback;, Low-dose- High frequency, firefighter
Nationell ämneskategori
Omvårdnad
Identifikatorer
URN: urn:nbn:se:hj:diva-50621DOI: 10.1108/IJES-03-2020-0010ISI: 000574268900001Scopus ID: 2-s2.0-85091387282OAI: oai:DiVA.org:hj-50621DiVA, id: diva2:1467247
Tillgänglig från: 2020-09-15 Skapad: 2020-09-15 Senast uppdaterad: 2025-10-13Bibliografiskt granskad

Open Access i DiVA

fulltext(304 kB)355 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 304 kBChecksumma SHA-512
7cb907f4916f93879920512d903f2d495cba27154cdb2d814b84e558cac282fbb295c82f9c071b7b7cc739bdbe46880399c1cb6f149baed6546c8741c7931ec4
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Abelsson, Anna

Sök vidare i DiVA

Av författaren/redaktören
Abelsson, Anna
Av organisationen
HHJ, Avd. för omvårdnad
I samma tidskrift
International Journal of Emergency Services
Omvårdnad

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 356 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 1069 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf