Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Stråldos till personals ögonlins vid CT-multitrauman.: En fantomstudie
Jönköping University, School of Health and Welfare, HHJ, Dep. of Nursing Science.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Nursing Science.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Radiation dose to staff´s eye lens at CT-multitrauma. A phantom study (English)
Abstract [sv]

Personal är utsatt för spridd strålning när de måste närvara vid CT trauman. Ögat är känsligt för joniserande strålning och det är bevisat att katarakt och strålning har ett samband. Vid CT-multitrauma används många projektioner och långa exponeringar. Studiens syfte är att undersöka hur mycket spridd strålning som personal utsätts för. Hur många gånger/år kan samma personal stå med innan rekommendationerna från ICRP på 20 mSv/år är uppnådd? Det är en kvantitativ studie som utförts empiriskt på två sjukhus med ett fantom. En Siemens 128 slice och en Toshiba 80 slice har använts vid mätningarna. Ett traumaprotokoll användes och en testmätning gjordes och därefter de riktiga mätningarna med dosimetrar från Landauer, placerade på sju mätpunkter i ögonhöjd på olika avstånd från gantryt. Den spridda strålningen var högst närmast gantryt och avtog med avståndet förutom två punkter som hade lägre mätresultat och kan förklaras på grund av dess vinkel från gantryt. Röntgensjuksköterskans ansvar är att informera om var personal bäst kan stå med vid CT trauman och att informera om vikten att variera personal.

Abstract [en]

Staff who has to attend CT-trauma examination is exposed to scattered radiation. The eye is sensitive to ionizing radiation and there is evidence that cataract and radiation are correlated. At CT-multitrauma long exposures and many projections is taken. The purpose of this study is to examine how much scattered radiation the staff is exposed to. How many times/year can one person in the staff attend a CT-trauma-examination before the ICRP recommendation dose of 20 mSv/year is reached? It is a quantitative study that has been done empirically at two hospitals with a phantom. A Siemens 128 slice and a Toshiba 80 slice were used in the measurements. A trauma protocol was used. One test measurement was done before the real measurements with dosimeters from Landuer placed at seven measure points at eye level at different distances from the gantry. The scattered radiation was highest close to the gantry and decreased with the distance except from two points that had lower measure results and this can be explained by the angle between the gantry and the dosimeter. It’s the radiographer’s responsibility to inform staff of the best place to stand at CT-trauma-examinations and to inform of the importance of alternating staff.   

Place, publisher, year, edition, pages
2016. , p. 24
Keywords [en]
Cataract, Computer tomography, Scattered radiation, Staff
Keywords [sv]
Katarakt, Datortomografi, Spridd strålning, Personal
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:hj:diva-30693ISRN: JU-HHJ-RAD-1-20160010OAI: oai:DiVA.org:hj-30693DiVA, id: diva2:940340
Subject / course
HHJ, Radiography
Available from: 2016-06-21 Created: 2016-06-20 Last updated: 2016-06-21Bibliographically approved

Open Access in DiVA

fulltext(921 kB)274 downloads
File information
File name FULLTEXT01.pdfFile size 921 kBChecksum SHA-512
ed796ed89116ef2b5448da35bd8a16660e4fea5568d33e0769a6693c8e9baa9e68073f5f88659a6e72e24bbcb8a722454f870f40e25ac0dd31ce5eb5d3cc919f
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Nursing Science
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 274 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 417 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf