Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fixerade elektroders betydelse för mängden uppkomna artefakter vid 24-timmars långtids-elektrokardiografi-registrering
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
The significance of fixated electrodes for the amount of artefacts that occur during 24-hour long-term electrocardiography-registration (English)
Abstract [sv]

Artefakter försvårar analys av långtids-elektrokardiografi-registrering (LTER) och resulterar i en försämrad diagnostisk säkerhet. Minimering av mängden artefakter spelar således en väsentlig roll för ställandet av rätt diagnos.

Syftet med denna studie var att jämföra om mängden artefakter, som uppkom vid 24-timmars LTER på patienter, skiljde sig åt med och utan fixering av elektroderna.

Populationen bestod av trettio patienter som var inbokade för 24-timmars LTER vid Länssjukhuset Ryhov i Jönköping. Patienterna delades in i två grupper med femton patienter i varje grupp. På grund av fyra externa bortfall bestod det slutgiltiga urvalet av tretton studiedeltagare i vardera gruppen. I grupp A användes ett tubnät för att hålla kablarna på plats och i grupp B fixerades varje elektrod och kabel med Mefix. Grupperna jämfördes sedan avseende mängden artefakter som uppkom under registreringsperioden. 

För att analysera om det förelåg någon signifikant skillnad i artefaktuppkomst mellan grupperna användes Wilcoxons rangsummetest. Rangsummorna för respektive grupp beräknades och jämfördes med ett kritiskt intervallvärde. Rangsummorna låg inom intervallet för det kritiska värdet, varpå nollhypotesen ej kan förkastas. Följaktligen förelåg ingen signifikant skillnad i mängden uppkomna artefakter mellan grupperna. På grund av ett litet urval samt brister i undersökningsförfarandet kunde dock inga grundade statistiska slutsatser konkluderas. 

Abstract [en]

Artefacts complicate the analysis of long-term electrocardiography-registration (LTER) and result in a worsened diagnostic accuracy. Thus, minimization of the amount of artefacts plays a vital role in the making of a correct diagnosis.

The aim of this study was to compare if the amount of artefacts that occurred during 24-hour LTER on patients, differed with and without electrode fixation. 

Thirty patients who underwent a 24-hour LTER, at Länssjukhuset Ryhov in Jönköping, were included in the study and divided into two groups. In group A; a tubular net bandage was used to keep the electrocardiography (ECG) cables in place. In group B, the electrodes and ECG cables were fixated with Mefix. A comparison was made, between the groups, regarding the amount of artefacts that occurred during the registration period. 

To analyze if there was a significant difference between the groups, Wilcoxon rank sum test was applied. The result proved to be within the range limits of the critical value, which implies that the null hypothesis cannot be rejected. Hence, there was no significant difference regarding the amount of artefacts that occurred. However, because of a small sample volume and shortfalls in the study procedure, no founded statistical conclusions could be drawn. 

Place, publisher, year, edition, pages
2016. , 23 p.
Keyword [en]
Ambulatory ECG, arrhythmias, signal-to-noise ratio
Keyword [sv]
Långtids-EKG, arytmier, signal-brus-förhållande
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:hj:diva-30484ISRN: JU-HHJ-BLA-1-20160014OAI: oai:DiVA.org:hj-30484DiVA: diva2:936184
External cooperation
Länssjukhuset Ryhov Jönköping
Subject / course
HHJ, Biomedical Laboratory Science
Supervisors
Examiners
Available from: 2016-06-15 Created: 2016-06-13 Last updated: 2016-06-15Bibliographically approved

Open Access in DiVA

fulltext(26731 kB)58 downloads
File information
File name FULLTEXT01.pdfFile size 26731 kBChecksum SHA-512
5f1bea43b51e9ab62339b14b40f83b59b834e8ac2b43ce9a2476adbec8ebc875442de7c7a6c2e3f95d4aefcbb28c6d7d5242c8b0c5df0ac0f8e8d3fb8820691f
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Natural Science and Biomedicine
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 58 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 27 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf