Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Utformning av projektorsystem
Jönköping University, School of Engineering, JTH, Mechanical Engineering.
2010 (Swedish)Independent thesis Advanced level (degree of Master (One Year)), 20 credits / 30 HE creditsStudent thesisAlternative title
Designing of a projector system (English)
Abstract [sv]

Det här examensarbetet på D-nivå har utförts i samarbete men företaget XM reality i Linköping. Företaget jobbar med att ta fram olika system inom området mixed reality, som på svenska översätts till förhöjd verklighet.

 

Syftet med projektet var att utforma två olika handhållna projektorsystem. Produkterna skulle utformas för att passa in i sjukhusmiljö. Båda enheterna har samma funktion men innehåller olika komponenter. Produkterna är anpassade till en ny teknik som företaget har utvecklat. Den nya tekniken är en mixed reality applikation som gör det möjligt att projicera skiktscanningar, CT eller MRI, direkt på patientens kropp. Målet med projektet var att göra två fungerade modeller. Modellerna skall fungera som prototyper i den medicinska forskarstudien som projektet ingår i.

 

En designstrategi utformades till företaget som skall uttrycka företagets image och vision. I arbetet med designstrategin togs ett antal kärnvärden fram. Kärnvärdena blev high tech, professionell, framtid, exklusiv, kvalité, hållbar samt kompakt vilket skall gälla för företagets samtliga produkter. Till produktsegmentet sjukhusprodukter tillades kärnvärdena ergonomisk samt dynamisk.

 

Arbetet med att utveckla produkterna började med litterära ergonomiska studier som följdes upp av fysiska användarstudier. Under arbetats gång har flera olika metoder tillämpats. Metoderna har används för att fatta beslut men även som stöd i den kreativa gestaltningsprocessen.

 

Resultatet är två ergonomiskt anpassade handhållna enheter. Enheterna är utformade för att passa in i sjukhusmiljön. De är smidiga samt enkla att använda. Båda produkterna är utformade efter designstrategin och för att förmedla företagets image. De fysiska modeller som gjordes innehåller fungerande komponenter som går att bytas ut.

 

Abstract [en]

This thesis D-level is done in collaboration with the company XM reality that is located in Linköping, Sweden. The company is working with the development of various systems in the field of mixed reality.

 

The task was to design two different hand-held projector systems. The products should be designed to fit in to the hospital environment. Both products have the same function but contain different components. The products are adapted to a new technology that the company has developed. The new technology is a mixed reality application that makes it possible to project CT or MRI scans directly on to the patient's body. The goal of the project was to make two functioning models. The models are to be used as prototypes in the medical research study the project is a part of.

 

A design strategy was created for the company to reflect the company’s image and vision. In the process of developing the design strategy, a number of core values were established. The core values were high-tech, professional, futuristic, exclusive, quality, durable and compact, which should to be valid for all the company’s products. To the product segment of hospital products were the core values ergonomic and dynamic added.

 

The work to develop the products began with literary ergonomic studies that were followed up by user studies. During the working process, several different methods were used. The methods were used not only to make decisions but also to help the creative design process.

 

The result is two ergonomically designed hand-held devices. The products are designed to fit into the hospital environment. They are slim and easy to use. Both products are designed along the design strategy and to communicate the company's image. The physical models that were made contain functional components that can be changed.

 

Place, publisher, year, edition, pages
2010. , p. 89
Keywords [sv]
Industridesign, Projektorsystem, Utformning, Mixed Reality, Augmented Reality, Sjukhus miljö, Handhållen
Identifiers
URN: urn:nbn:se:hj:diva-13320OAI: oai:DiVA.org:hj-13320DiVA, id: diva2:353814
Uppsok
Technology
Supervisors
Examiners
Available from: 2010-12-29 Created: 2010-09-29 Last updated: 2010-12-29Bibliographically approved

Open Access in DiVA

fulltext(26067 kB)177 downloads
File information
File name FULLTEXT01.pdfFile size 26067 kBChecksum SHA-512
037533922387c1dc15d6d7a3c18166eded654ce171eb089990775b516cbbe7f639838f723f9394e0fb205039d51ec883f0c2f62ba244863718555e7c523a367a
Type fulltextMimetype application/pdf

By organisation
JTH, Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 177 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 373 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf