Fire Resistance in Cross-laminated Timber: Brandmotstånd hos korslaminerat massiv trä
Jönköping University, School of Engineering, JTH, Civil Engineering.
2010 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

This report deals with the fire resistance of cross-laminated timber (CLT). Themain purpose is to verify a new model on CLT and its ability to sustain itsbearing capacity when exposed to fire. To establish this, a series of bendingtestshas been conducted in combination with fire exposure of the CLT. Twodifferent series, with different dimensions, of beams were tested (series 1 andseries 2). Four basic set-ups: CLT in tension or compression, either equippedwith fire protective covering or not. Results from the tests has been gatheredand evaluated to verify the theoretical model of the fire resistance. Evaluationwas made through analysis of the residual cross-sections of the beamsregarding charring depth and rate and moment of inertia (I).Results of the tests verify to a large extent the Design model. Externalproblems and variations in the beams themselves caused some deviations.Analysis confirmed the CLT as being more similar to other laminated productssuch as Laminated Veneer Lumber (LVL) then homogenous solid beams. BothCLT and LVL experience delamination when exposed to fire resulting in anincreased charring rate. The difference in rate when using Gypsum plaster as aprotective barrier against the fire exposure is also equal to LVL.The results of the report will be used in the new version of the EuropeanStandard, Euro Code 5 and in the third edition of Fire Safe Timber Buildings.Charring rates proved to be less than expected but the CLTs ability to withstandfire while keeping its bearing capacity

Place, publisher, year, edition, pages
2010. , p. 79
Keywords [en]
Cross-laminated timber, CLT Bearing capacity, Fire resistance, Bending tests, SP Wood Technology
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:hj:diva-11653OAI: oai:DiVA.org:hj-11653DiVA, id: diva2:299665
Presentation
(English)
Uppsok
Technology
Supervisors
Examiners
Available from: 2010-02-25 Created: 2010-02-23 Last updated: 2010-02-25Bibliographically approved

Open Access in DiVA

fulltext(2168 kB)2812 downloads
File information
File name FULLTEXT01.pdfFile size 2168 kBChecksum SHA-512
92dd5ae6f27841c00efc9338f4140cdd7a8ccc3e6d737cf378add02e4ed9b3615b87a3096d4cd7ed7c135d28ba98766ce9db960904d78970693c243d8febd1b8
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Wilinder, Per
By organisation
JTH, Civil Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 2971 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1526 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf