Stråldoser vid bukundersökningar med dubbelenergi-datortomografi och enkelenergi-datortomografi: En retrospektiv empirisk studie
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE credits
Student thesisAlternative title
Radiation doses in abdominal examinations with dual-energy computed tomography and single-energy computed tomography (English)
Abstract [sv]
Antalet datortomografi (DT)-undersökningar har ökat markant under senaste decennierna och parallellt med detta så har tekniken utvecklats avsevärt. Dubbelenergi-DT är en relativ ny teknik som har uppkommit efter enkelenergi-DT teknik. DT-undersökningar medför höga patientdoser därför är syftet med denna studie att jämföra stråldoser mellan dubbelenergi-DT och enkelenergi-DT. Studien är av kvantitativ ansats och retrospektiv datainsamling. Deltagarna som har uppfyllt urvalskriterierna omfattades i studien och uppdelades i fyra grupper för att kunna jämföra stråldoser mellan kön och båda modaliteterna. Antalet deltagare som inkluderades i studien var 569 och dessa har utförts på Länssjukhuset Ryhov i Jönköping. Data har bearbetats i SPSS där varje grupp i respektive kön har ställts mot varandra för att se om det finns stråldosskillnad. Variablerna som testades var Dose length product (DLP), Computed tomography dose index by volume (CTDIvol) och mAs. Resultatet visar att enkelenergi-DT gav en högre DLP och CTDIvol samt en lägre mAs. Resultatet av denna studie styrks av resultat av andra forskningsstudier som kommit till liknande slutsatser.
Abstract [en]
Computed tomography (CT) examinations have increased markedly in recent decades and, in parallel with this, the technology has developed considerably. Dual-energy CT is a relatively new technology that has emerged after single-energy CT technology. CT examinations involve high patient doses, and therefore the purpose of this study is to compare radiation doses between new and old technology. The study is of a quantitative approach and retrospective data collection. Participants who met the selection criteria were included in the study and divided into four groups to allow comparison of radiation doses between genders and both modalities. The number of participants included in the study was 569 and these were performed at Ryhov County Hospital in Jönköping. Data were processed in SPSS where each group in each gender was compared against each other to see if there was a radiation dose difference. The variables tested were Dose length product (DLP), Computed tomography dose index by volume (CTDIvol) and mAs. The results show that single-energy CT gave a higher DLP and CTDIvol and a lower mAs. The results of this study are supported by the results of other research studies that have come to similar conclusions.
Place, publisher, year, edition, pages
2024. , p. 41
Keywords [en]
ALARA principle, DECT, iodine contrast medium, patient radiation dose, SECT
Keywords [sv]
ALARA-principen, DECT, jodkontrastmedel, patientstråldos, SECT
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:hj:diva-64954OAI: oai:DiVA.org:hj-64954DiVA, id: diva2:1871087
Subject / course
HHJ, Radiography
Supervisors
Examiners
2024-06-172024-06-162024-06-17Bibliographically approved