Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Utvärdering av Siemens Innovance® Anti-FXa metod på Sysmex CS-2100i för kvantifiering av Rivaroxaban
Jönköping University, School of Health and Welfare, HHJ, Dept. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dept. of Natural Science and Biomedicine.
2022 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Evaluation of Siemens Innovance® Anti-FXa method in Sysmex CS-2100i for quantification of Rivaroxaban (English)
Abstract [sv]

Rivaroxaban är ett direkt oral antikoagulantia läkemedel (DOAK) som bland annat används för behandling av djup ventrombos. Rivaroxaban är ett antikoagulantia som inhiberar koagulationsfaktor Xa i koagulationsprocessen. Eftersom allt fler patienter förskrivs Rivaroxaban behöver laboratoriet på Länssjukhuset Ryhov utvärdera metoden för att kunna erbjuda analys av detta läkemedel i rutinverksamheten. Syftet med detta arbete var att utvärdera analysmetoden anti-FXa på Sysmex CS-2100i för DOAK läkemedlet Rivaroxaban. Metodutvärderingen omfattade utvärdering av repeterbarhet och mellanliggande precision i samband med analys av låg och hög kontroll. Jämförelse med validerad metod omfattade analys patientplasma och spädda kalibratorer. Bestämning av lägsta detektionsvärde utfördes på plasma från blodgivare. Koncentrationen av Rivaroxaban bestämdes kvantitativt med en enzymatisk kromogen metod. Repeterbarhet och mellanliggande precision var godkänd. Jämförelse med validerad metod för patientprover gav en god överrensstämmelse för metoderna. Men för få prover analyserades för tillförlitligt värde. Kalibratorerna gav mycket god överensstämmelse för det teoretiska och det uppmätta värdet, men antalet analyserade prover var begränsat. Bestämning av lägsta detektionsvärde resulterade i värden mellan 0-5 ng/ml, under Siemens satta gräns och kan justeras för Länssjukhuset Ryhov. Slutsatsen blir att metoden är validerad och kan användas på Länssjukhuset Ryhov.  

Abstract [en]

Rivaroxaban is a direct oral anticoagulant drug (DOAK) used to treat, e.g., deep vein thrombosis. Rivaroxaban inhibits coagulation factor Xa in the coagulation process. More doctors prescribe Rivaroxaban thus, the laboratory at Länssjukhuset Ryhov needs to evaluate the method. Evaluation will enable the laboratory to offer the analysis in routine practice. The purpose of this study was to evaluate anti-FXa assay on Sysmex CS-2100i for the DOAK drug Rivaroxaban. The method evaluation included the evaluation of repeatability and intermediate precision in connection with the analysis of low and high controls. Comparison with validated method analyzed patient plasma and diluted calibrators. Analysis of lowest detection value analyzed plasma from blood donors. The concentration of Rivaroxaban was determined quantitatively by an enzymatic chromogenic method. Repeatability and intermediate precision were approved. Comparison with a validated method for patient samples gave comparable results for the methods, but too few samples were analyzed for reliable values. The calibrators generated high correlation between the theoretical and measured values. Analysis of the lowest detection value gave values between 0-5 ng/ml. The manufacturer’s set limit can therefore be adjusted for Länssjukhuset Ryhov. In conclusion the method is validated at Länssjukhuset Ryhov. 

Place, publisher, year, edition, pages
2022. , p. 19
Keywords [en]
Chromogenic substrate assay, factor Xa, DOAK, Validation study, Coagulation
Keywords [sv]
Kromogen substratmetod, Faktor Xa, DOAK, Metodvalidering, Koagulation
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:hj:diva-56986ISRN: JU-HHJ-BLA-1-20220123OAI: oai:DiVA.org:hj-56986DiVA, id: diva2:1666915
Subject / course
HHJ, Biomedical Laboratory Science
Available from: 2022-06-13 Created: 2022-06-09 Last updated: 2022-06-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
HHJ, Dept. of Natural Science and Biomedicine
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 344 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf