Assessment of function of a 3D-printed body-powered upper limb prosthetic device
Jönköping University, School of Health and Welfare, HHJ, Dep. of Rehabilitation.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Rehabilitation.
2019 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Purpose

Conventional arm-prosthesis are expensive to make and therefore limit the availability for users on the geographical locations there the user pays for it. This study compares the hand function of a 3D-printed prosthesis with lower production cost with a traditional prosthesis.

Method

A test person performed two different tests of hand function (Box and Block test and Nine-hole peg test) with a myoelectric trans radial prosthetic arm and a body powered 3D printed trans radial prosthetic arm. The test person also answered two parts of the orthotics and prosthetics users’ survey (OPUS) considering both prosthetic arms.

Result

The 3D-printed prosthesis performed worse than the traditional prosthesis in the two tests of hand function and generally worse in the questionnaire about the function of the prosthesis. Though it got higher values in comfort and affordability.

Conclusion

There was a significant difference in function between the 3D-printed prosthesis and the myoelectric prosthesis but the printed prosthesis could perform many activities in daily living. Whether the 3D-printed prosthetic device is priceworthy or not is hard to measure because of different criteria, therefore a conclusion is hard to reach.

Place, publisher, year, edition, pages
2019. , p. 32
Keywords [en]
RIT-arm, hand function, Box and block test, nine-hole peg test, OPUS
National Category
Medical Materials
Identifiers
URN: urn:nbn:se:hj:diva-44578ISRN: JU-HHJ-OTE-1-20190034OAI: oai:DiVA.org:hj-44578DiVA, id: diva2:1326244
Subject / course
HHJ, Prosthetic and Orthotic
Supervisors
Examiners
Available from: 2019-06-26 Created: 2019-06-17 Last updated: 2019-06-26Bibliographically approved

Open Access in DiVA

fulltext(2293 kB)9 downloads
File information
File name FULLTEXT01.pdfFile size 2293 kBChecksum SHA-512
0d6556db8894cbcdc1ae7df932173cd8c223c888b3fcd3c95443bb6417f80858872937769e7c36b58b4aa2fb7f5c683cb34b81e1267d0f44cc1720f75dcd93cd
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Broman, AdamBlom, Gustav
By organisation
HHJ, Dep. of Rehabilitation
Medical Materials

Search outside of DiVA

GoogleGoogle Scholar
Total: 9 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 51 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf