Visualization of multimodal polymer-shelled contrast agents using ultrasound contrast sequences: An experimental study in a tissue mimicking flow phantom
KTH, Medicinsk teknik.ORCID iD: 0000-0002-4757-7232
KTH, Medicinsk teknik.ORCID iD: 0000-0002-5795-9867
Show others and affiliations
2013 (English)In: Cardiovascular Ultrasound, ISSN 1476-7120, E-ISSN 1476-7120, Vol. 11, 33- p.Article in journal (Refereed) Published
Abstract [en]

Background: A multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim of this study was therefore to investigate the acoustic response by studying the visualization capability and shadowing effect of three polymer-shelled CAs when using optimized sequences for contrast imaging. Methods: The acoustic response of three types of the multimodal CA was evaluated in a tissue mimicking flow phantom setup by measuring contrast to tissue ratio (CTR) and acoustic shadowing using five image sequences optimized for contrast imaging. The measurements were performed over a mechanical index (MI) range of 0.2-1.2 at three CA concentrations (10(6), 10(5), 10(4) microbubbles/ml). Results: The CTR-values were found to vary with the applied contrast sequence, MI and CA. The highest CTR-values were obtained when a contrast sequence optimized for higher MI imaging was used. At a CA concentration of 106 microbubbles/ml, acoustic shadowing was observed for all contrast sequences and CAs. Conclusions: The CAs showed the potential to enhance ultrasound images generated by available contrast sequences. A CA concentration of 106 MBs/ml implies a non-linear relation between MB concentration and image intensity.

Place, publisher, year, edition, pages
2013. Vol. 11, 33- p.
Keyword [en]
Acoustic shadowing, Contrast agent, Contrast sequences, Contrast to tissue ratio, Flow phantom, Multimodal
National Category
Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:hj:diva-37084DOI: 10.1186/1476-7120-11-33ISI: 000324140500001Scopus ID: 2-s2.0-84883074083OAI: oai:DiVA.org:hj-37084DiVA: diva2:1137235
Available from: 2013-10-03 Created: 2017-08-30Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Larsson, MalinLarsson, MatildaBjällmark, Anna
In the same journal
Cardiovascular Ultrasound
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 1 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf