En jämförelse mellan mättekniker för högerkammarbedömning vid ekokardiografi: Överensstämmelse mellan s´ och TAPSE
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
A comparison of measure techniques for right ventricular function assessment in echocardiography : Correlation between s´ and TAPSE (English)
Abstract [sv]

Bedömningen av höger kammares systoliska funktion kan med fördel göras med ekokardiografi, bl.a. med tekniker som tvådimensionell ekokardiografi, motion-mode (M-mode) och Tissue Doppler Imaging (TDI). Mätvärden som kan fås ut av dessa tekniker är Tricuspid Annular Plane Systolic Excursion (TAPSE) och s`. TAPSE beskriver annulus tricuspidalis longitudinella rörlighet. s´ beskriver den maximala systoliska hastigheten i annulus tricuspidalis. Syftet med examensarbetet var att undersöka sambandet mellan TAPSE och s´ vid högerkammarfunktionsbestämning. Studien är en retrospektiv tvärsnittsstudie och består av 99 deltagare i åldrarna 18–90 år. Både friska och hjärt-och kärlsjuka deltagare inkluderades, men inte patienter med förmaksflimmer eller individer som var yngre än 18 år. Deltagarna undersöktes med transthorakal ekokardiografi (TTE) vid Länssjukhuset Ryhov i Jönköping, vid undersökningen mättes TAPSE och s´. Det var samma biomedicinska analytiker (BMA) som utförde undersökningarna. McNemars test utfördes och ett Kappa-värde räknades ut. Resultatet visade signifikant skillnad och Kappa-värdet var lågt vilket talar för dåligt samband mellan de båda variablerna. Utfallet i studien visar att fler deltagare klassas med normal högerkammarfunktion mätt med TAPSE, medan samma individer klassas med högerkammardysfunktion mätt med s´. Orsaken till det dåliga sambandet mellan parametrarna är okänt och bör studeras vidare i kommande studier. 

Abstract [en]

The assessment of right ventricular systolic function is done by echocardiography, with techniques as twodimensional echocardiography, motion-mode (M-mode) and Tissue Doppler Imaging (TDI). Measurements ​​obtained from these techniques are Tricuspid Annular Plane Systolic Excursion (TAPSE) and s`. TAPSE describes the longitudinal movement of annulus tricuspidalis. s´ describes annulus tricuspidalis maximal systolic velocity. The purpose of this essay was to explore the relationship between TAPSE and s´. The study consists of 99 participants between the ages of 18 and 90. The population was consisted of individuals with or without cardiovascular disease, but not individuals with atrial fibrillation. Participants were investigated with transthorakal echocardiography (TTE) at Länssjukhuset Ryhov in Jönköping. At the examination both TAPSE and s´ was measured. McNemar's test was performed and a Kappa value was calculated. The result showed a significant difference and the Kappa value was low which indicates a low relationship between the variables. The outcome of the study shows that several participants are classified with normal right ventricular function measured with TAPSE, but the same individuals are classified with right ventricular dysfunction measured by s'. The reason for the poor relationship between the parameters is unknown and should be studied further in future studies.

Place, publisher, year, edition, pages
2017. , 18 p.
Keyword [en]
annulus tricuspidalis movement, motion-mode, tissue doppler imaging, right ventricle function
Keyword [sv]
annulus tricuspidalis rörlighet, motion-mode, tissue doppler imaging, högerkammarfunktion
National Category
Clinical Laboratory Medicine
Identifiers
URN: urn:nbn:se:hj:diva-35877ISRN: JU-HHJ-BLA-1-20170036OAI: oai:DiVA.org:hj-35877DiVA: diva2:1106476
External cooperation
Länssjukhuset Ryhov
Subject / course
HHJ, Biomedical Laboratory Science
Supervisors
Examiners
Available from: 2017-06-09 Created: 2017-06-07 Last updated: 2017-06-09Bibliographically approved

Open Access in DiVA

En jämförelse mellan mättekniker för högerkammarbedömning vid ekokardiografi: Överensstämmelse mellan s´ och TAPSE(1209 kB)76 downloads
File information
File name FULLTEXT01.pdfFile size 1209 kBChecksum SHA-512
d45f8fff463e2c522b1ced531ed7b02f7a7a52b466d0fff368a74d277ab55f98343708311434395441d6b0d62a56f6014197cbdb0af3113889db6cb6bd49eec5
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Natural Science and Biomedicine
Clinical Laboratory Medicine

Search outside of DiVA

GoogleGoogle Scholar
Total: 76 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 73 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf