Utformning av fördröjningsdammar, medavseende på rening av dagvatten fråntransport- och lagerhållningsindustri
Jönköping University, School of Engineering, JTH, Civil Engineering.
Jönköping University, School of Engineering, JTH, Civil Engineering.
2012 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Design of storm water ponds, with regard to treatmentof storm water from transportation and warehousingindustry (English)
Abstract [sv]

För att recipienter nedströms inte ska påverkas av dagvatten från industriområdenmed transport och lagerhållning, krävs det rening av föroreningar. Därför har detgjorts en undersökning av hur en dagvattendamm ska utformas för att få en ökadrening. Metoder som används är litteraturstudie och en fallstudie. Fallstudien harutförts för ett planerat industriområde. De frågor som besvarats är vilkaföroreningar som kan tänkas förekomma och hur de renas. Vidare har detstuderats vilka egenskaper som påverkar reningen i en dagvattendamm.Studieresultaten visade att de vanligast förekommande föroreningarna ärtungmetaller, miljöfarliga organiska ämnen och näringsämnen. Det har ocksåframkommit att dessa föroreningar, i huvudsak renas genom sedimentation ochväxtupptag. Vidare har det kommit fram att det inte finns någon standardlösningför hur en dagvattendamm ska utformas, med tanke på rening. Detta eftersom alladammar har olika yttre förutsättningar som styr utformningen, vilka beror på detområde där dammen ligger. Det har dock visats sig att det finns ett antal olikavägledande parametrar som bör beaktas för att få en god reningseffekt i dammen.De viktigaste av dessa är dammens hydrauliska och hydrologiska effektivitet.

Abstract [en]

Receiving waters downstream should not be affected by storm water from storageand transport industry, therefore it requires treatment of pollution. The objectiveof this study has been to show how a storm water pond should be designed toachieve a good treatment. The methods used are a literature review, and a casestudy. The case study has been performed for a planned industrial area. Thequestions which needed to be answered are the type of pollutants that might occurand how they are treated. Furthermore, it has been studied which properties affectthe purification in a storm water pond.The results of the study showed that the most pollutants were heavy metals, toxicorganic matter and nutrients. It has also become apparent that these pollutants, ismainly treated by sedimentation and absorption by plants. Furthermore, it hasemerged that there is no standard for how a storm water pond should bedesigned, with regards to the treatment. This is because all ponds have differentexternal conditions that control the design, which depends on the area where thepond is located. However, it has been shown that there are a number ofparameters that should be taken into account, in order to get a high treatmenteffect in the pond. The most important of these is the hydraulic and hydrologicalefficiency of the pond.

Place, publisher, year, edition, pages
2012. , p. 52
Keywords [sv]
Dagvattendammar, Dagvattenrening, Fördröjningsdammars utformning, Föroreningar, Hydraulik, Sedimentation
National Category
Water Engineering
Identifiers
URN: urn:nbn:se:hj:diva-18560OAI: oai:DiVA.org:hj-18560DiVA, id: diva2:535358
Subject / course
JTH, Civil Engineering; JTH, Civil Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-06-21 Created: 2012-06-19 Last updated: 2013-05-13Bibliographically approved

Open Access in DiVA

fulltext(1979 kB)1077 downloads
File information
File name FULLTEXT01.pdfFile size 1979 kBChecksum SHA-512
975a5b5d5fe070d1475b8cda2dee236c2f13af1bbedf3c457dc31e3e25bb096ff7bc5f121bcf27ce841f2cf026288cae54e231c2cd787ae94d388a53e0372c6d
Type fulltextMimetype application/pdf

By organisation
JTH, Civil Engineering
Water Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1077 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1166 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf