Planned maintenance
A system upgrade is planned for 10/12-2024, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Tätning eller ventilering mot fukt på kalla vindsutrymmen
Jönköping University, School of Engineering, JTH, Civil Engineering.
Jönköping University, School of Engineering, JTH, Civil Engineering.
Jönköping University, School of Engineering, JTH, Civil Engineering.
2006 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 points / 15 hpStudent thesis
Abstract [en]

This study was done regarding whether sealing or ventilation is the best solution to prevent moisture on cold attics. The authors of this report addressed the problem with moisture in attics when they started their cooperation with Peab.

The methods included interviews with people, database research, and calculations of a project in Akersberga north of Stockholm. The conclusion is based on interviews and other information as they are analyzed in relation to the house of reference. The focus of this report is on problems with moisture in the attics known as cold attics.

The background of the problem with moisture is that today’s slabs are usually insulated to save energy and that the attics nearly gives the climate as the outdoor climate. The contribution of moisture increases this problem when the relative humidity reaches 75 %, which in most cases promotes mould. Moisture comes with natural ventilation through the eaves due to outside humidity and precipitation finding its way in, and at the same time comes from the inside through openings or cracks on concrete slabs, ventilation ducts, and attic doors.

Moisture also comes into the attic from building materials, especially from the concrete slabs that evaporate which gives off a lot of moisture throughout the years. These things are possible to prevent with four different methods ventilation, sealing, heating or insulating the outer roof.

Moisture effects are calculated from the examples given by Roxull FuktFakta in comparison with the authors own calculations from other databases. The object of reference, Bergahojden 6, is a residential building that has served as a model for all the calculations. The conclusion shows that air circulation has to increase to get out the moisture through the ventilation. The winters here in Sweden are so humid that the ventilation should be suitable enough so that the humidity does not rise above 75 % in the attic.

To heat up the attic with devices, or by using roof insulation, would bring the same climate as the outdated slab insulations. There will be a big loss of energy with heat going out if the roof is not insulated. To apply both systems would be a double investment which would be hard to convince builders of.

The conclusion is that the best method would be to combine sealing with ventilation, or a possible mechanical system which allows the attic to be ventilated during the summer and sealed during the winter.

Place, publisher, year, edition, pages
2006. , p. 124
Keywords [sv]
Fukt, Vind, Kondens, Mögel, Uttorkning, Ventilera, Täta, Ånghalt
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:hj:diva-517OAI: oai:DiVA.org:hj-517DiVA, id: diva2:4227
Uppsok
teknik
Supervisors
Examiners
Available from: 2006-08-09 Created: 2006-08-09

Open Access in DiVA

fulltext(10943 kB)4405 downloads
File information
File name FULLTEXT01.pdfFile size 10943 kBChecksum SHA-1
1a2f71b936317407275268ee78b077dea5fd9bd27556fd3837f437c5e7194ce06dd180dc
Type fulltextMimetype application/pdf

By organisation
JTH, Civil Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 4405 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1165 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf