Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Endocardial border delineation capability of a multimodal polymer-shelled contrast agent
KTH Royal Institute of Technology, Stockholm, Sweden.
KTH Royal Institute of Technology, Stockholm, Sweden and Karolinska Institutet, Solna, Sweden.
Karolinska Institutet, Stockholm, Sweden.
Università di Roma Tor Vergata, Rome, Italy.
Show others and affiliations
2014 (English)Conference paper, Poster (with or without abstract) (Other academic)
Abstract [en]

Background

A novel polymer-shelled contrast agent (CA) with high mechanical and chemical stability was recently developed [1]. In excess to its ultrasound properties, it also supports targeted and multimodal imaging [2-4]. Even though these new possibilities have the potential to lead to new methodologies and approaches for non-invasive diagnosis, it is important that the fundamental diagnostic features in contrast-enhanced ultrasound are preserved. The aim of this study was therefore to examine the clinical use of the polymer-shelled CA by analyzing the left ventricular endocardial border delineation capability in a porcine model. In addition, physiological effects due to CA injections were studied.

Methods

The endocardial border delineation capability was assessed in a comparative study, which included three doses (1.5 ml, 3 ml and 5 ml, [5x108 MBs/ml]) of the polymer-shelled CA and the commercially available CA SonoVue® (1.5 ml, [2-5x108 MBs/ml]). Ultrasound images of the left ventricle were evaluated manually by blinded observers (n=3) according to a 6-segment model, in which each segment was graded as 0=not visible, 1=barely visible or 2=well visible, as well as semi-automatically by a segmentation software. Furthermore, duration of clinically useful contrast enhancement and changes in physiological parameters were evaluated.

Results

For the highest dose of the polymer-shelled CA, the obtained segment scores, time for clinically sufficient contrast enhancement and semi-automatic delineation capability were comparable to SonoVue®. Moreover, neither dose of the polymer-shelled CA did affect the physiological parameters.

Conclusion

This study demonstrated that the polymer-shelled CA can be used in contrast-enhanced diagnostic imaging without influence on major physiological parameters.

Place, publisher, year, edition, pages
2014.
National Category
Medical Image Processing
Identifiers
URN: urn:nbn:se:hj:diva-42170OAI: oai:DiVA.org:hj-42170DiVA, id: diva2:1267042
Conference
19th European Symposium on Ultrasound Contrast Imaging 23-24 January, 2014, Rotterdam, The Netherlands
Available from: 2018-11-30 Created: 2018-11-30 Last updated: 2018-11-30Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records

Bjällmark, Anna

Search in DiVA

By author/editor
Bjällmark, Anna
Medical Image Processing

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 83 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf