Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Validation of gait analysis with dynamic radiostereometric analysis (RSA) in patients operated with total hip arthroplasty
Gothenburg University, Institute of Clinical Sciences, Section for Anesthesiology, Biomaterials and Orthopaedics, Department of Orthopaedics.
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Journal of Orthopaedic Research, ISSN 0736-0266, E-ISSN 1554-527X, Vol. 35, nr 7, s. 1515-1522Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We simultaneously examined 14 patients with OTS and dynamic radiostereometric analysis (RSA) to evaluate the accuracy of both skin- and a cluster-marker models. The mean differences between the OTS and RSA system in hip flexion, abduction, and rotation varied up to 9.5° for the skin-marker and up to 11.3° for the cluster-marker models, respectively. Both models tended to underestimate the amount of flexion and abduction, but a significant systematic difference between the marker and RSA evaluations could only be established for recordings of hip abduction using cluster markers (p = 0.04). The intra-class correlation coefficient (ICC) was 0.7 or higher during flexion for both models and during abduction using skin markers, but decreased to 0.5-0.6 when abduction motion was studied with cluster markers. During active hip rotation, the two marker models tended to deviate from the RSA recordings in different ways with poor correlations at the end of the motion (ICC ≤0.4). During active hip motions soft tissue displacements occasionally induced considerable differences when compared to skeletal motions. The best correlation between RSA recordings and the skin- and cluster-marker model was found for studies of hip flexion and abduction with the skin-marker model. Studies of hip abduction with use of cluster markers were associated with a constant underestimation of the motion. Recordings of skeletal motions with use of skin or cluster markers during hip rotation were associated with high mean errors amounting up to about 10° at certain positions. 

Ort, förlag, år, upplaga, sidor
John Wiley & Sons, 2017. Vol. 35, nr 7, s. 1515-1522
Nationell ämneskategori
Ortopedi
Identifikatorer
URN: urn:nbn:se:hj:diva-40506DOI: 10.1002/jor.23415ISI: 000404354200019PubMedID: 27591554Scopus ID: 2-s2.0-85021267877OAI: oai:DiVA.org:hj-40506DiVA, id: diva2:1220285
Tillgänglig från: 2018-06-18 Skapad: 2018-06-18 Senast uppdaterad: 2018-10-16Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Sök vidare i DiVA

Av författaren/redaktören
Tranberg, Roy
I samma tidskrift
Journal of Orthopaedic Research
Ortopedi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 20 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf