Performance of personally worn dosimeters to study non-image forming effects of light: Assessment methods
Eindhoven University of Technology, Eindhoven, The Netherlands.
Eindhoven University of Technology, Eindhoven, The Netherlands.
Högskolan i Jönköping, Tekniska Högskolan, JTH, Byggnadsteknik och belysningsvetenskap. Eindhoven University of Technology, Eindhoven, The Netherlands.ORCID-id: 0000-0001-7520-1593
Eindhoven University of Technology, Eindhoven, The Netherlands.
2017 (engelsk)Inngår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 117, s. 60-72Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

When determining the effects of light on human beings, it is essential to correctly measure the effects, and to correctly measure the adequate properties of light. Therefore, it is important to know what is being measured and know the quality of the measurement devices. This paper describes simple methods for identifying three quality indices; the directional response index, the linearity index and the temperature index. These indices are also checked for several commonly used portable light measurement devices. The results stresses what was already assumed, the quality and the outcome of these devices under different circumstances were very different. Also, the location were these devices are normally worn has an impact on the results. The deviation range between worn vertically at eye level and the wrist is between 11% (outdoor) to 27% (indoor). The smallest deviation, both in indoor and outdoor, was found when the device was placed on the sides of the eye (7%). 

sted, utgiver, år, opplag, sider
Elsevier, 2017. Vol. 117, s. 60-72
Emneord [en]
Device, Dosimeter, Light, Method, NIF, Performance, Buildings, Civil engineering, Directional response, Image forming, Measurement device, Quality indices, Temperature index, Dosimeters
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-35273DOI: 10.1016/j.buildenv.2017.03.002ISI: 000400226300006Scopus ID: 2-s2.0-85015064414Lokal ID: JTHBebyggdISOAI: oai:DiVA.org:hj-35273DiVA, id: diva2:1085527
Tilgjengelig fra: 2017-03-29 Laget: 2017-03-29 Sist oppdatert: 2018-09-17bibliografisk kontrollert

Open Access i DiVA

fulltext(6250 kB)151 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 6250 kBChecksum SHA-512
2f012f20b8624833f575370524c6bd7537836b4bcffe0650f749b9c42cdbadd6b65ba43dc0ef4b162a0904a70d0cc0d1c7ccad1da974b113f7d9a977225beddf
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Aries, Myriam B. C.

Søk i DiVA

Av forfatter/redaktør
Aries, Myriam B. C.
Av organisasjonen
I samme tidsskrift
Building and Environment

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 151 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 1609 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf