An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
Department of Radiology, Ryhov County Hospital, Jönköping, Sweden.
Department of Radiology, Ryhov County Hospital, Jönköping, Sweden.
Department of Clinical Physiology, Kalmar County Hospital, Kalmar, Sweden.
Högskolan i Jönköping, Hälsohögskolan, HHJ, Avd. för naturvetenskap och biomedicin. Department of Oncology, Hospital Physics, Ryhov County Hospital, Jönköping, Sweden.ORCID-id: 0000-0002-3951-7715
Vise andre og tillknytning
2017 (engelsk)Inngår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 37, nr 1, s. 52-61Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo–echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.

Methods: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.

Results: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).

Conclusion: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2017. Vol. 37, nr 1, s. 52-61
Emneord [en]
cardiac imaging techniques, coronary heart disease, Magnetic Resonance Imaging, nuclear medicine, perfusion
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-34807DOI: 10.1111/cpf.12267ISI: 000390688200008PubMedID: 26147785Scopus ID: 2-s2.0-84936803283OAI: oai:DiVA.org:hj-34807DiVA, id: diva2:1067098
Tilgjengelig fra: 2017-01-20 Laget: 2017-01-20 Sist oppdatert: 2017-11-29bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Starck, Sven-Åke

Søk i DiVA

Av forfatter/redaktør
Starck, Sven-Åke
Av organisasjonen
I samme tidsskrift
Clinical Physiology and Functional Imaging

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 459 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf