Radiografisk undersökning av belastade knän vid artrosfrågeställning: Jämförelse av stråldoser och undersökningstid
Högskolan i Jönköping, Hälsohögskolan, HHJ, Avd. för naturvetenskap och biomedicin.
Högskolan i Jönköping, Hälsohögskolan, HHJ, Avd. för naturvetenskap och biomedicin.
2015 (Svenska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Radiographic examination of congested knees with osteoarthritis issue : Comparison of radiation doses and the examination time (Engelska)
Abstract [sv]

Syfte: Att jämföra patientens totala stråldos och undersökningstid från metoderna konventionell röntgen och genomlysning vid undersökningen belastade knän med artrosfrågeställning.

Metod: Datainsamlingen utfördes genom att det delades ut dosprotokoll där röntgensjuksköterskorna på röntgenavdelningen fick skriva upp stråldoser och undersökningstid. Datainsamlingen gjordes under en fyraveckorsperiod på ett medelstort sjukhus i Sverige. Datainsamlingen jämfördes genom en hypotesprövning där det utfördes ett Mann-Whitney U-test med en signifikansnivå på fem procent för att se om nollhypotesen (ingen skillnad i stråldos eller tid) höll.

Resultat: Studiens nollhypotes för stråldoserna förkastades som hade medelvärdet 444,37 mGycm² (genomlysning) och 212,24 mGycm² (konventionell röntgen). Nollhypotesen för undersökningstiderna förkastades också som hade medelvärdena 5,08 minuter (genomlysning) och 8,48 minuter (konventionell röntgen). Signifikansnivån för båda faktorerna var lägre än 0,001 och därför behölls mothypoteserna att det fanns en skillnad mellan modaliteterna.

Slutsats: Studiens resultat visade att konventionell röntgen är den bäst lämpade metoden att använda stråldosmässigt medan genomlysningen är bäst lämpad tidsmässigt. Vilken metod som är lämpligast att använda som standard beror på olika faktorer som stråldos, undersökningstid, bildkvalité och ergonomi. Därför behövs det fler studier för att kunna sammanställa vilken metod som är bäst att använda för alla dessa faktorer.

Abstract [en]

Purpose:  To compare the patient's total radiation dose and the examination time from the methods conventional radiography and fluoroscopy during the examination congested knees with osteoarthritis issue.

Method:  Data was collected by handing a dose protocol in which the radiographers in the radiology department were asked to write down the doses of radiation and the examination time. Data was collected over a period of four weeks in a medium-sized hospital in Sweden. The data collection was compared by one-tail test where a Mann-Whitney U-test was performed with a significant level of five percent to see if the null hypothesis (no difference in the radiation dose or time) was obtained.

Results:  The study's null hypothesis regarding radiation doses was rejected due to that an average of 444.37 mGycm² (fluoroscopy) and 212.24 mGycm² (conventional radiography) was obtained. The study’s null hypothesis regarding the examination times had an average of 5.08 minutes (fluoroscopy) and 8.48 minutes (conventional radiography). As significant levels of both factors was less than 0.001 the alternative hypothesis was retained due to a difference between the modalities.

Conclusion:  The study results showed that conventional radiography is the most appropriate method to use regarding radiation dose rate while fluoroscopy is best suited in terms of time. Witch method is most appropriate to use as a standard depends on various factors such as radiation dose, examination time, image quality and ergonomics. Therefore further studies is suggested to compile which method is best to use for all these factors.

Ort, förlag, år, upplaga, sidor
2015. , s. 35
Nyckelord [en]
Conventional X-ray, fluoroscopy, osteoarthritis, radiation dose, examination time
Nyckelord [sv]
Konventionell röntgen, genomlysning, artros, stråldos, undersökningstid
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:hj:diva-27345ISRN: JU-HHJ-RAD-1-20150003OAI: oai:DiVA.org:hj-27345DiVA, id: diva2:823879
Ämne / kurs
HHJ, Radiografi
Handledare
Examinatorer
Tillgänglig från: 2015-06-22 Skapad: 2015-06-18 Senast uppdaterad: 2016-06-16Bibliografiskt granskad

Open Access i DiVA

fulltext(1010 kB)535 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1010 kBChecksumma SHA-512
4285b8ee52732e980d2573c1c07dd9c97c0d067244392234c1e5dd6abfc630f4b6c8e19c583883e0196e6e4e792bd96c93a5f58dd7ba8c001e1e3c701e0b7c5d
Typ fulltextMimetyp application/pdf

Av organisationen
HHJ, Avd. för naturvetenskap och biomedicin
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 535 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 366 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf