Fire Resistance in Cross-laminated Timber: Brandmotstånd hos korslaminerat massiv trä
Högskolan i Jönköping, Tekniska Högskolan, JTH, Byggnadsteknik.
2010 (Engelska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

This report deals with the fire resistance of cross-laminated timber (CLT). Themain purpose is to verify a new model on CLT and its ability to sustain itsbearing capacity when exposed to fire. To establish this, a series of bendingtestshas been conducted in combination with fire exposure of the CLT. Twodifferent series, with different dimensions, of beams were tested (series 1 andseries 2). Four basic set-ups: CLT in tension or compression, either equippedwith fire protective covering or not. Results from the tests has been gatheredand evaluated to verify the theoretical model of the fire resistance. Evaluationwas made through analysis of the residual cross-sections of the beamsregarding charring depth and rate and moment of inertia (I).Results of the tests verify to a large extent the Design model. Externalproblems and variations in the beams themselves caused some deviations.Analysis confirmed the CLT as being more similar to other laminated productssuch as Laminated Veneer Lumber (LVL) then homogenous solid beams. BothCLT and LVL experience delamination when exposed to fire resulting in anincreased charring rate. The difference in rate when using Gypsum plaster as aprotective barrier against the fire exposure is also equal to LVL.The results of the report will be used in the new version of the EuropeanStandard, Euro Code 5 and in the third edition of Fire Safe Timber Buildings.Charring rates proved to be less than expected but the CLTs ability to withstandfire while keeping its bearing capacity

Ort, förlag, år, upplaga, sidor
2010. , s. 79
Nyckelord [en]
Cross-laminated timber, CLT Bearing capacity, Fire resistance, Bending tests, SP Wood Technology
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:hj:diva-11653OAI: oai:DiVA.org:hj-11653DiVA, id: diva2:299665
Presentation
(Engelska)
Uppsök
teknik
Handledare
Examinatorer
Tillgänglig från: 2010-02-25 Skapad: 2010-02-23 Senast uppdaterad: 2010-02-25Bibliografiskt granskad

Open Access i DiVA

fulltext(2168 kB)2844 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2168 kBChecksumma SHA-512
92dd5ae6f27841c00efc9338f4140cdd7a8ccc3e6d737cf378add02e4ed9b3615b87a3096d4cd7ed7c135d28ba98766ce9db960904d78970693c243d8febd1b8
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Wilinder, Per
Av organisationen
JTH, Byggnadsteknik
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 3018 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1533 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf