Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent
KTH, Medicinsk bildteknik.ORCID-id: 0000-0002-4757-7232
KTH, Medicinsk bildteknik.ORCID-id: 0000-0002-5795-9867
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Cardiovascular Ultrasound, E-ISSN 1476-7120, Vol. 12, s. 24-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. Methods: Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 x 10(8) microbubbles (MBs)/ml]) and the commercially available CA SonoVue (1.5 ml [2-5 x 10(8) MBs/ml]) were used. Visual evaluations of ultrasound images of the left ventricle were independently performed by three observers who graded each segment in a 6-segment model as either 0 = not visible, 1 = weakly visible, or 2 = visible. Moreover, the duration of clinically useful contrast enhancement and the left ventricular opacification were determined. During anesthesia, oxygen saturation, heart rate, and arterial pressure were sampled every minute and the effect of injection of CA on these physiological variables was evaluated. Results: The highest dose of the polymer-shelled CA gave results comparable to SonoVue. Thus, no significant difference in the overall segment score distribution (2-47-95 vs. 1-39-104), time for clinically sufficient contrast enhancement (20-40 s for both) and left ventricular overall opacification was found. In contrast, when comparing the endocardial border delineation capacity for different regions SonoVue showed significantly higher segment scores for base and mid, except for the mid region when injecting 1.5 ml of the polymer-shelled CA. Neither high nor low doses of the polymer-shelled CA significantly affected the investigated physiological variables. Conclusions: This study demonstrated that the novel polymer-shelled CA can be used in contrast-enhanced diagnostic imaging without influence on major physiological variables.

Ort, förlag, år, upplaga, sidor
2014. Vol. 12, s. 24-
Nyckelord [en]
Contrast agent, Echocardiography, Endocardial border delineation, Microbubbles, Polyvinyl alcohol, Porcine, Ultrasound
Nationell ämneskategori
Kardiologi och kardiovaskulära sjukdomar
Identifikatorer
URN: urn:nbn:se:hj:diva-37083DOI: 10.1186/1476-7120-12-24ISI: 000338893900001Scopus ID: 2-s2.0-84910120890OAI: oai:DiVA.org:hj-37083DiVA, id: diva2:1137233
Tillgänglig från: 2014-08-12 Skapad: 2017-08-30 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Bjällmark, Anna

Sök vidare i DiVA

Av författaren/redaktören
Larsson, Malin K.Larsson, MatildaJanerot Sjöberg, BirgittaBjällmark, Anna
I samma tidskrift
Cardiovascular Ultrasound
Kardiologi och kardiovaskulära sjukdomar

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 107 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf