Accuracy and precision of a technique to assess residual limb volume with a measuring-tape
Högskolan i Jönköping, Hälsohögskolan, HHJ, Avd. för rehabilitering.
2003 (Engelska)Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
Abstract [en]

Transtibial stump volume can change dramatically postoperatively and jeopardise prosthetic fitting. Differences between individuals make it hard to give general recommendations of when to fit with a definitive prosthesis. Measuring the stump volume on every patient could solve this, but most methods for volume assessments are too complicated for clinical use.

The aim of this study was to evaluate accuracy and intra- and interrater precision of a method to estimate stump volume from circumferential measurements. The method approximates the stump as a number of cut cones and the tip as a sphere segment.

Accuracy was evaluated theoretically on six scanned stump models in CAPOD software and manually on six stump models. Precision was evaluated by comparing measurements made by four CPOs on eight stumps. Measuring devices were a wooden rule and a metal circumference rule. The errors were estimated with intraclass correlation coefficient (ICC), where 0,85 was considered acceptable, and a clinical criterion that a volume error of ±5% was acceptable (5% corresponds to one stocking).

The method was accurate on all models in theory but accurate on only four models in reality. The ICC was 0,95-1,00 for intrarater precision but only 0,76 for interrater precision. Intra- and interrater precision was unsatisfying when using clinical criteria. Variations between estimated tip heights and circumferences were causing the errors.

The method needs to be developed and is not suitable for stumps with narrow ends. Using a longer rule (about 30 cm) with a set square end to assess tip heights is recommended to improve precision. Using a flexible measuring-tape (possible to disinfect) with a spring-loaded handle could improve precision of the circumferential measurements.

sted, utgiver, år, opplag, sider
2003. , s. 62
Emneord [en]
accuracy, errors of measurement, precision, prostheses, transtibial, volume.
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-1247OAI: oai:DiVA.org:hj-1247DiVA, id: diva2:3699
Uppsök
medicin
Veileder
Examiner
Tilgjengelig fra: 2008-05-23 Laget: 2008-05-23

Open Access i DiVA

fulltekst(1610 kB)2679 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1610 kBChecksum MD5
51bc516ca46c339fc10e787c3cb5298dbddbabc6b9e3bcc62ff230d62f98a84a0da88069
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 2682 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 597 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf