Fire Resistance in Cross-laminated Timber: Brandmotstånd hos korslaminerat massiv trä
Högskolan i Jönköping, Tekniska Högskolan, JTH, Byggnadsteknik.
2010 (engelsk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [en]

This report deals with the fire resistance of cross-laminated timber (CLT). Themain purpose is to verify a new model on CLT and its ability to sustain itsbearing capacity when exposed to fire. To establish this, a series of bendingtestshas been conducted in combination with fire exposure of the CLT. Twodifferent series, with different dimensions, of beams were tested (series 1 andseries 2). Four basic set-ups: CLT in tension or compression, either equippedwith fire protective covering or not. Results from the tests has been gatheredand evaluated to verify the theoretical model of the fire resistance. Evaluationwas made through analysis of the residual cross-sections of the beamsregarding charring depth and rate and moment of inertia (I).Results of the tests verify to a large extent the Design model. Externalproblems and variations in the beams themselves caused some deviations.Analysis confirmed the CLT as being more similar to other laminated productssuch as Laminated Veneer Lumber (LVL) then homogenous solid beams. BothCLT and LVL experience delamination when exposed to fire resulting in anincreased charring rate. The difference in rate when using Gypsum plaster as aprotective barrier against the fire exposure is also equal to LVL.The results of the report will be used in the new version of the EuropeanStandard, Euro Code 5 and in the third edition of Fire Safe Timber Buildings.Charring rates proved to be less than expected but the CLTs ability to withstandfire while keeping its bearing capacity

sted, utgiver, år, opplag, sider
2010. , s. 79
Emneord [en]
Cross-laminated timber, CLT Bearing capacity, Fire resistance, Bending tests, SP Wood Technology
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-11653OAI: oai:DiVA.org:hj-11653DiVA, id: diva2:299665
Presentation
(engelsk)
Uppsök
Technology
Veileder
Examiner
Tilgjengelig fra: 2010-02-25 Laget: 2010-02-23 Sist oppdatert: 2010-02-25bibliografisk kontrollert

Open Access i DiVA

fulltekst(2168 kB)2843 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2168 kBChecksum SHA-512
92dd5ae6f27841c00efc9338f4140cdd7a8ccc3e6d737cf378add02e4ed9b3615b87a3096d4cd7ed7c135d28ba98766ce9db960904d78970693c243d8febd1b8
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Wilinder, Per
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 3015 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1533 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf