Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Pulsed tissue Doppler imaging for the detection of myocardial ischaemia, a comparison with myocardial perfusion SPECT
County Hospital Ryhov, Jönköping, Sweden.
County Hospital Ryhov, Jönköping, Sweden.
County Hospital Ryhov, Jönköping, Sweden.
Linköping Heart Centre, University Hospital, Linköping, Sweden.
Vise andre og tillknytning
2004 (engelsk)Inngår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 24, nr 5, s. 289-295Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In order to compare the diagnostic ability of pulsed tissue Doppler and myocardial perfusion Single Photon Emission Computed Tomography (SPECT) in patients with a history of unstable coronary artery disease, CAD, 26 patients, 22 men and four women, age 47-76 years, were investigated in a prospective study, 5-10 day after an episode of unstable angina. Tissue Doppler and two-dimensional echocardiography were performed during dobutamine stress testing and myocardial scintigraphy after bicycle exercise and at rest. Patients with a normal SPECT had higher peak systolic velocity during dobutamine infusion, 18.9 ± 4.1 cm s-1, than patients with ischaemia, 12.2 ± 3.8 cm s-1 (P<0.001) or scar, 8.8 ± 3.0 cm s-1 (P<0.01). In a territorial analysis the difference in peak systolic velocity between areas with a normal and abnormal SPECT was less apparent. Failure to achieve ≥13 cm s-1 in mean-peak systolic velocity was the most accurate criterion for detection of significant CAD on SPECT. We conclude that pulsed tissue Doppler can be used for objective quantification of left ventricular wall motion during dobutamine stress testing and for identification of patients with CAD on SPECT but not for identification of regional ischaemia.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2004. Vol. 24, nr 5, s. 289-295
Emneord [en]
Dobutamine, Echocardiography, Myocardial perfusion SPECT, Tissue Doppler, atropine, tetrofosmin tc 99m, adult, aged, article, bicycle ergometry, clinical article, clinical trial, controlled clinical trial, controlled study, diagnostic value, Doppler echocardiography, drug infusion, female, heart left ventricle contraction, heart left ventricle wall motion, heart perfusion, human, image analysis, intermethod comparison, ischemic heart disease, male, priority journal, prospective study, rest, scintillation camera, single photon emission computer tomography, statistical significance, stress echocardiography, two dimensional echocardiography, unstable angina pectoris
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-63328DOI: 10.1111/j.1475-097X.2004.00564.xISI: 000224000700007PubMedID: 15383086Scopus ID: 2-s2.0-5444273567OAI: oai:DiVA.org:hj-63328DiVA, id: diva2:1827059
Tilgjengelig fra: 2024-01-12 Laget: 2024-01-12 Sist oppdatert: 2025-02-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Blomstrand, Peter

Søk i DiVA

Av forfatter/redaktør
Blomstrand, Peter
I samme tidsskrift
Clinical Physiology and Functional Imaging

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 22 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf