Utvärdering av INNOVANCE D-Dimer reagens
Jönköping University, Hälsohögskolan, HHJ, Avdelningen för naturvetenskap och biomedicin.
Jönköping University, Hälsohögskolan, HHJ, Avdelningen för naturvetenskap och biomedicin.
2023 (svensk)Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgaveAlternativ tittel
Evaluation of the INNOVANCE D-Dimer reagent (engelsk)
Abstract [sv]

D-Dimer är en nedbrytningsprodukt av fibrinogen som bland annat indikerar trombossjukdomar vid höga nivåer. D-Dimer är inte specifik nog för att användas för definitiv diagnos, därför används analys av D-Dimer vanligtvis som ett uteslutningstest då trombossjukdomar misstänks. Den enhet som idag används för att rapportera D-Dimer-resultat vid Klinisk kemi, Ryhov i Jönköping är D-Dimer Units. För att kunna standardisera metoderna som används för analys av D-Dimer utvärderades INNOVANCE® D-Dimer-reagenset vilket är baserat på rapportering av analysresultat i enheten Fibrinogen Equivalent Units. Analys av D-Dimer har orsakat problem på grund av dess heterogenitet och många olika befintliga analysmetoder. Dessutom skapas oklarhet kring resultatrapportering på grund av användning av olika enheter. Syftet med denna studie var att utvärdera INNOVANCE® D-Dimer reagens vid Klinisk kemi, Ryhov för att införa användningen av Fibrinogen Equivalent Units. Metodutvärderingen inkluderade repeterbarhetstest och mellanliggande precision med hjälp av INNOVANCE® kontroller och analys av patientprover. Resultaten av patientproverna jämfördes med resultaten från samma patientprover vid Lunds Universitetssjukhus och Sahlgrenska Universitetssjukhus. Korrelationen mellan samtliga resultat visade tydliga samband. Slutsatsen blev att INNOVANCE® D-Dimer reagens är godkänt för implementering på Klinisk kemi, Ryhov.

Abstract [en]

D-Dimer is a fibrinogen degradation product which indicates thrombotic diseases, amongst other conditions, when reported in high levels. It is more frequently used as an exclusion test when suspecting thrombotic diseases due to the occurrence of high levels of D-Dimer in various conditions. The unit which is currently used for D-Dimer analysis at Clinical chemistry, Ryhov Jönköping is D-Dimer Units. In attempt to standardize the method used for analysis of D-Dimer, the INNOVANCE® D-Dimer reagent was evaluated. INNOVANCE® D-Dimer reagent is reported in the unit Fibrinogen Equivalent Units. Analysis of D-Dimer causes problems due to its heterogeneity and the many existing methods of analysis. The many ways of reporting results in different units are also creating confusion. The purpose of this study was to evaluate INNOVANCE® D-Dimer reagent at Clinical chemistry, Ryhov to introduce usage of Fibrinogen Equivalent Units. The method evaluation included repeatability test and intermediate precision using the INNOVANCE® Controls and analyzing patient samples. The results of the patient samples were compared to the results obtained from the same samples at Lunds University hospital and Sahlgrenska University hospital. There was a clear correlation between all instruments and institutions. In conclusion, INNOVANCE® D-Dimer was approved for introduction at Clinical chemistry, Ryhov.

sted, utgiver, år, opplag, sider
2023. , s. 20
Emneord [en]
Coagulation, Clinical chemistry, Fibrinogen degradation product, Fibrinogen Equivalent Units, Validation
Emneord [sv]
Koagulation, Klinisk kemi, FIbrinogennedbrytningsprodukt, Fibrinogen Equivalent Units, Validering
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-61465ISRN: JU-HHJ-BLA-1-20230143OAI: oai:DiVA.org:hj-61465DiVA, id: diva2:1772644
Fag / kurs
HHJ, Biomedical Laboratory Science
Veileder
Examiner
Tilgjengelig fra: 2023-06-22 Laget: 2023-06-21 Sist oppdatert: 2023-06-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Søk i DiVA

Av forfatter/redaktør
Andersson, WilmaGrönlund, Julia
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 46 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf