Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
En jämförelse mellan respiratorisk polygrafi och perifer arteriell tonometri i diagnos av obstruktiv sömnapné
2019 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
A comparison between Peripheral Arterial Tonometry and polygraphy in the diagnosis of Obstructive Sleep Apnea (engelsk)
Abstract [sv]

Bakgrund: Obstruktiv sömnapné (OSA) är en av de vanligaste kroniska sömnsjukdomarna. Sjukdomen kännetecknas av återkommande episoder med andningsuppehåll under sömn. Detta ligger till grund för dagsömnighet och utveckling av systemsjukdomar. Det finna goda behandlingsalternativ för OSA som CPAP (continuous positive airway pressure), bettskena och kirurgi. Respiratorisk polygrafi (hädanefter presenterad som ”polygrafi”) är standardmetoden i Sverige för att diagnosticera OSA. Perifer arteriell tonometri (PAT) är en alternativ metod. Det finns olika kriterier för tolkning av polygrafi. Detta gör det svårt att jämföra studier. Svenska sömnapnéregistret (SESAR) och berörda specialitetsföreningar har därför tagit fram svenska nationella diagnoskriterier för sömnapné, SESAR-kriterierna. Syfte: Syftet med studien var att utreda om indexvärdena, AHI (apné-hypopné index) och ODI (oxygen desaturation index) överensstämmer i totalen och i olika positioner (rygg och icke-rygg) mellan PAT och polygrafi (tolkad med SESAR-kriterierna), samt att undersöka om det föreligger någon systematisk skillnad mellan dem. Material och metod: Elva patienter registrerades med polygrafi (NOX-T3) och PAT(WatchPAT) under en och samma natt. Registreringarna tolkades med SESAR kriterierna och WatchPAT scoring guidelines. Resultat: PAT visade en stark positiv korrelation med polygrafi (Spearman’s rho=0,771–0,963). Slutsats: Ingen signifikant skillnad hittades mellan PAT och polygrafi.

Abstract [en]

Background: Obstructive sleep apnea (OSA) is the most common chronic sleep disorder. The disease is characterized by recurrent episodes of respiratory arrest during sleep. This is the basis for daytime sleepiness and development of common systemic diseases. There are good treatment options for OSA including CPAP (continuous positive airway pressure), mandibular advancement splints and surgery. Respiratory polygraphy (hereinafter referred to as “polyhraphy”) is the standard method in Sweden for diagnosing OSA. Peripheral arterial tononometry (PAT) is an alternative method. There are different criteria for interpretation of polygraphy, thus making it difficult to compare studies. Svenska sömnapnéregistret (SESAR) and relevant speciality associations have therefore developed a Swedish national diagnostic criterion for sleep apnea, the SESAR-criteria. Purpose: To investigate if PAT and polygraphy (interpreted with the SESAR-criteria), correspond in apnea-hypopnea index (AHI) and oxygen desaturation index (ODI) and if there is any systematic difference between the methods in different positions (supine and non-supine). Material and methods: Eleven patients were registered with polygraphy (NOX-T3) and PAT (WatchPAT) for one night. The registrations were interpreted with the SESAR-criteria and the WatchPAT scoring guidelines, respectively. Results: PAT showed a strong positive correlation with polygraphy (Spearman’s rho=0,771-0,963). Conclusion: No significant difference was found between methods.

sted, utgiver, år, opplag, sider
2019. , s. 30
Emneord [en]
Apnea-hypopnea index, oxygen desaturations index, respiratory effort related arousals, SESAR-criteria and polysomnography
Emneord [sv]
Apné-hypopné index, oxygen desaturations index, respiratory effort related arousals, SESAR-kriterier och polysomnografi
HSV kategori
Identifikatorer
URN: urn:nbn:se:hj:diva-44382ISRN: JU-HHJ-BLA-1-20190078OAI: oai:DiVA.org:hj-44382DiVA, id: diva2:1323308
Fag / kurs
HHJ, Biomedical Laboratory Science
Veileder
Examiner
Tilgjengelig fra: 2019-06-13 Laget: 2019-06-11 Sist oppdatert: 2019-06-13bibliografisk kontrollert

Open Access i DiVA

fulltext(646 kB)22 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 646 kBChecksum SHA-512
7910b9cfcfa52bc034e5b9e014c3f4132063b3eb1ef082090739fc7ddf5db782aa28667f2528275ceb62a86ad40031ff05c0ab9ed7da25172a8c1b5ca2436e70
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Starck, AntonAl-Obaidi, Marwah

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 22 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 35 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf