Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Viabilitet av Neisseria gonorrhoeae, Propionibacterium acnes och Bacteroides fragilis vid förlängd förvaring i transportröret COPAN E-swab™
Jönköping University, School of Health Science, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health Science, HHJ, Dep. of Natural Science and Biomedicine.
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Viability of Neisseria gonorrhoeae, Propionibacterium acnes and Bacteroides fragilis under prolonged storage in the transporttube COPAN E-swab™ (English)
Abstract [sv]

En säker bakteriediagnostik kräver en korrekt provtagningsteknik, ett lämpligt transportsätt och rätt odlingsteknik. På grund av centralisering av verksamheter och ekonomiska begräsningar, är transport av prover till mikrobiologilaboratorium mycket vanligt. Detta medför behov av ett transportmedium som håller känsliga bakterier vid liv under långa transport- och förvaringstider. Dessutom skall transportrören klara av maskinell utodling som kräver ett vätskebaserat provtagningsmedium. Denna övergång minskar även arbetsbelastning och förbättra ergonomin hos personalen. I denna studie utvärderades viabilitet av Propionibacterium acnes (n=3), Bacteroides fragilis (n=2) och Neisseria gonorrhoeae (n=3) i transportmediet från COPAN E-swab™. Alla tre bakterier förvarades i transportrören i 24, 48 och 72 timmar (h) och dessutom i 120h för P. acnes och B. fragilis. Den ursprungliga koncentrationen samt den procentuella viabilitetsförlusten över tid beräknades med hjälp av viable count. Efter 120h förvaring i transportmediet hade viabiliteten minskat till 47 – 80 % för P. acnes, 18 % för B. fragilis 1 och 73 % för B. fragilis 2. N. gonorrhoeae visade en minskad viabilitet med 96 – 99,97 % efter 24h förvaring i 4°C och rumstemperatur. P. acnes och B. fragilis kunde förvaras i transportmediet i upp till 5 dygn utan att diagnostiken äventyrades. N. gonorrhoeae kunde förvaras i transportmediet i 24h för att diagnostik genom odling ska vara möjlig.

Abstract [en]

Safe bacterial diagnostics requires proper sampling techniques, suitable specimen transport and correct inoculation techniques. As a result of centralization of operations and economic restraints, transportation of samples to microbiology laboratories is very common. This entails the need for a transport medium that keeps sensitive bacteria alive under the long transport and storage time. Additionally, the transport tube should be convenient for automatic inoculation that requires a liquid based medium. This transition also reduces workload and improves ergonomics of the staff. In this study the survival of Propionibacterium acnes (n = 3), Bacteroides fragilis (n = 2) and Neisseria gonorrheae (n = 3) in the transport medium Copan E-swab™   was evaluated. All the species were inoculated in the tubes for 24, 48, 72h and also 120h for B. fragilis and P. acnes.  Initial concentration at start time and the percentage survival over time was calculated with the help of viable count. Viability decreased to 47 – 80 % for P. acnes, 18 % for B. fragilis 1 and 73% for B. fragilis 2 after 120 h storage in the transportmedium. N. gonorrhoeae showed a reduction in viability of 96 – 99,97 % after 24h storage in the medium at 4°C and in room temperature. P. acnes and B. fragilis can be stored in the medium for up to 5 days, without endangering a diagnosis. N. gonorrhoeae can be stored in the transport medium for up to 24h to secure a diagnosis through culturing.

Place, publisher, year, edition, pages
2015. , p. 23
Keywords [en]
viable count, fastidious, anaerobic, bacteria, storage
Keywords [sv]
viable count, krävande, anaeroba, bakterier, förvaring
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:hj:diva-27060ISRN: JU-HHJ-BLA-1-20150003OAI: oai:DiVA.org:hj-27060DiVA, id: diva2:818979
Subject / course
HHJ, Biomedical Laboratory Science
Supervisors
Examiners
Available from: 2015-06-10 Created: 2015-06-09 Last updated: 2015-06-10Bibliographically approved

Open Access in DiVA

fulltext(154 kB)386 downloads
File information
File name FULLTEXT01.pdfFile size 154 kBChecksum SHA-512
8b373e785577b973a60aa1563e6908e62342ada2259acc6dcd3866db996d427f823fde745f5e975c57be912c8ae74326f94ef9e728773bd3bf33b3169d7881e0
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Nord, SabineKassim, Hussein
By organisation
HHJ, Dep. of Natural Science and Biomedicine
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 386 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 343 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf