Utvärdering av sensitivitet och specificitet för Acro Biotech Multitest 15 vid drogscreening
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
Jönköping University, School of Health and Welfare, HHJ, Dep. of Natural Science and Biomedicine.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Evaluation of sensitivity and specificity of Acro Biotech Multitest 15 at drug screening (English)
Abstract [sv]

Akut- och psykiatriska avdelningar på länssjukhuset Ryhov i Jönköping använder sig av snabbtest för drogscreening med varierande kvalitet under de tider då analysinstrumentet Konelab Prime 30i inte är bemannat. Syftet med studien var att utvärdera sensitivitet och specificitet hos Multitest 15 från tillverkaren Acro Biotech, och jämföra resultat från två olika avläsningstider. Antalet urinprover som samlades in för analys uppgick till 272. Positiva och negativa urinprover med drogkoncentrationer inom ±50% från varje drogs gränsvärde insamlades. Senare inkluderades drogkoncentrationer utanför detta intervall. Proverna testades med Multitest 15 vid laboratoriet för klinisk kemi på Ryhov efter utförd analys med Konelab Prime 30i, vars analysresultat utgjorde referens. De droger som testades var amfetamin, metamfetamin, ecstasy, bensodiazepiner, buprenorfin, kokain, metadon, morfin, THC, oxykodon och tramadol. För alla droger sammantaget var sensitiviteten 86,7% - 100%, specificiteten 33,3% - 100% och träffsäkerheten 71,4% - 94,7%. Provurvalet inom intervallet ±50% från gränsvärdet var begränsat, vilket avsevärt påverkat dessa beräkningar, och Konelab Prime 30i använder semikvantitativ metod vilken endast ger approximativa koncentrationsvärden som referens.

Abstract [en]

The emergency and psychiatric wards on the county hospital Ryhov in Jönköping utilize onsite drug testing with varying quality during evenings and night-time when no staff are operating the chemistry analyzer Konelab Prime 30i. The aim of the study is to evaluate the performance of sensitivity and specificity of Acro Biotech Multitest 15 and comparing results from two different reading-times. The number of urine samples collected for analysis was 272. Positive and negative urine samples with drug concentrations within ± 50% from cut-off were collected. Later, concentrations outside of this range was included. The samples were tested with Multitest 15 at the laboratory for clinical chemistry at Ryhov after analysis with Konelab Prime 30i providing reference results. The drugs tested were amphetamine, methamphetamine, ecstasy, benzodiazepines, buprenorphine, cocaine, methadone, morphine, THC, oxycodone and tramadol. All drugs included, the sensitivity was 86.7% - 100%, the specificity 33% - 100% and the accuracy 71.4% - 94.7%. The sample selection within the range ±50% from the cut-off value was limited, which significantly affected these calculations, and Konelab Prime 30i uses a semi-quantitative method only providing approximate concentration values for reference.

Place, publisher, year, edition, pages
2019. , p. 23
Keywords [en]
One-site testing, Cut-off value, Accuracy, Urine, Drugs
Keywords [sv]
Snabbtest, Gränsvärde, Träffsäkerhet, Urin, Droger
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:hj:diva-44931ISRN: JU-HHJ-BLA-1-20190087OAI: oai:DiVA.org:hj-44931DiVA, id: diva2:1330549
External cooperation
Länssjukhuset Ryhov
Subject / course
HHJ, Biomedical Laboratory Science
Supervisors
Examiners
Available from: 2019-06-26 Created: 2019-06-25 Last updated: 2019-06-26Bibliographically approved

Open Access in DiVA

fulltext(577 kB)171 downloads
File information
File name FULLTEXT01.pdfFile size 577 kBChecksum SHA-512
25cc809cd74a9522363a7d0c8afa46d2cd7d385adba210d4edcb9d53f65c431a5ac77d15f430414aa7ec7842be4d941de30c9228f21b74d1f8725510900fb117
Type fulltextMimetype application/pdf

By organisation
HHJ, Dep. of Natural Science and Biomedicine
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 171 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 194 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf