Användning av glas i kontorsbyggnader: Fokus på energi- och koldioxidutsläpp
Jönköping University, School of Engineering, JTH, Civil Engineering.
Jönköping University, School of Engineering, JTH, Civil Engineering.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Use of glass in office buildings (English)
Abstract [sv]

Syfte: Att undersöka effekterna vid ersättning av större delar av fasader ikontorsbyggnader med glas, där fokus ligger på energianvändning samtkoldioxidutsläpp.

Metod: Kvalitativa semistrukturerade intervjuer, litteraturstudier och dokumentanalys.

Resultat: En kontorsbyggnad studerades med hänsyn till den specifikaenergianvändningen och koldioxidutsläppen. Glasarean och fasadarea beräknades förden befintliga byggnaden. Sedan utökades glasarean i fasaden från 30 % till 50respektive 70 %. Resultatet visade att en ökning från 30 % till 50 % minskade denspecifika energianvändningen för samtliga fyra energiberäkningar som utfördes iGöteborg, Lund, Stockholm och Umeå. Däremot ökade den specifikaenergianvändningen för samtliga fall vid en ökning från 50 % till 70 %. Vid analyseringav koldioxidutsläppen fick man fram att koldioxidhalten alltid minskade vid ökning avglasarea.

Konsekvenser: Rapporten visar tydligt att det finns ett problem gällandeenergiförbrukning och koldioxidutsläpp idag. Byggregler och råd ska följas utavbyggbranschen för att uppnå målen som EU har satt upp. Studien visar att det finns etttydligt samband mellan koldioxidutsläppen och ökningen av glasarean dock saknadesdetta samband för energianvändningen.

Begränsningar: Arbetet begränsas till att undersöka en kontorsbyggnad medbetongstomme belägen i Göteborg, Stockholm, Lund och Umeå. Glasets arkitektoniskaperspektiv behandlas inte och påverkar därav inte val eller placering av glaspartier,glaset har inte några bärande egenskaper.

Abstract [en]

Purpose: To investigate the effects of replacing major parts of facades in officebuildings with glass, focusing on the energy use and the carbon dioxide emissions

Method: Qualitative semi- structured interviews, literature studies and documentanalysis.

Findings: An office building was studied with regard to the specific energy use andcarbon dioxide emissions. The glass area and façade area were calculated for theexisting building. Then the glass area was expanded from 30 % to 50% and 70%respectively. The result showed that an increase from 30% to 50% decreased thespecific energy use for all four energy calculations carried out in Gothenburg, Lund,Stockholm and Umeå. On the other hand, the specific energy use for all cases increasedwhen expanding the glass area from 50% to 70%. When analyzing carbon dioxideemissions, it was found that the carbon dioxide content always reduced as a result ofthe increasing glass area.Implications: The report clearly shows that there is a problem regarding energyconsumption and carbon dioxide emissions today. Building rules and advice should befollowed by the construction industry in order to achieve the goals set by the EU. Thestudy shows that there is a clear connection between carbon dioxide emissions and theincrease in the glass area, however, this connection was lacking for the energy use.

Limitations: The work is limited to investigating an office building with concreteframes located in Gothenburg, Stockholm, Lund and Umeå. The architecturalperspective of the glass is not considered and therefore it does not influence theselection nor does placement of the glass portions, the glass have no bearing attributes.

Place, publisher, year, edition, pages
2017. , p. 41
Keywords [en]
Glass facades, life cycle analyzes, energy analyzes.
Keywords [sv]
Glasfasader, livscykelanalyser, energianalyser.
National Category
Architectural Engineering
Identifiers
URN: urn:nbn:se:hj:diva-36430ISRN: JU-JTH-BTA-1-20170158OAI: oai:DiVA.org:hj-36430DiVA, id: diva2:1115658
External cooperation
Skanska Sverige AB Region Hus Väst/skaraborg
Subject / course
JTH, Civil Engineering
Supervisors
Examiners
Available from: 2017-08-15 Created: 2017-06-27 Last updated: 2017-08-15Bibliographically approved

Open Access in DiVA

fulltext(6066 kB)211 downloads
File information
File name FULLTEXT01.pdfFile size 6066 kBChecksum SHA-512
0ab925fd686fcf2f10f60445207ef91509b3bd409e9daa91235f10b416aca879fcff27ad8e78d7e954e049df973f2859f66a72146b96d47ba83229c0df5ce4ff
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Moucho, MohammadkarimFarhat, Nader
By organisation
JTH, Civil Engineering
Architectural Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 211 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 279 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf